GX-Series Control Panel Installation and Setup Guide
B-6
Ev SIA Event Log Log Event Ev Type Contact
Description Event Description Trigger ID
Event
FAULT RST USER 20.FAULT 313
PF RESET USER 20.FAULT 313
P - Panic
PA Panic Alarm PA+ PA zone alarm ZONE 1.PA/DURE 120
DELAY ALM+ PA Delay zone alarm ZONE 1.PA/DURE 120
PB Panic Bypass OMITTED PA zone omitted ZONE 8.OMIT 573
FORCEOMT+ Force omit after rearm ZONE 8.OMIT 573
PJ Pan Troub rest LOW RES- Restor zone resistance ZONE 15.TROUBL 380
HIGH RES- Restor zone resistance ZONE 15.TROUBL 380
PR Panic Restoral PA- PA zone restored ZONE 1.PA/DURE 120
18.ZN RESTO
DELAY ALM- PA Delay zone restored ZONE 1.PA/DURE 120
18.ZN RESTO
PT Panic Trouble LOW RES+ Low resistance on zone ZONE 15.TROUBL 380
HIGH RES+ High resistance on zone ZONE 15.TROUBL 380
PU Panic Unbypas FORCE OMT- Unomitted after rearm ZONE 8.OMIT 573
Q - Assist (Custom SIA - see note 2)
QA Alarm Note 1 zone in alarm ZONE 5.CUS ZON Note 1
QB Bypass OMITTED zone omitted ZONE 8.OMIT 573
FORCEOMT+ Force omit after rearm ZONE 8.OMIT 573
QJ Trouble Rest LOW RES- Restor zone resistance ZONE 15.TROUBL 380
HIGH RES- Restor zone resistance ZONE 15.TROUBL 380
QR Alarm Restore Note 1 zone restored ZONE 5.CUS ZON Note 1
18.ZN RESTO
QT Trouble LOW RES+ Low resistance on zone ZONE 15.TROUBL 380
HIGH RES+ High resistance on zone ZONE 15.TROUBL 380
QU Unbypass FORCE OMT- Unomitted after rearm ZONE 8.OMIT 573
R - Remote,Log,Test
RB REM LOG USER NONE 0
REM RESET USER NONE 0
REM ID USER NONE 0
REM COPY USER NONE 0
REM OVRWR USER NONE 0
REM MSG USER NONE 0
COPY SITE MODULE NONE 0
OVWR SITE MODULE NONE 0
RC Relay closed LINK- Link zone closed ZONE 16.LOG 150
LOG- Log zone closed ZONE 16.LOG 150
LOG DELAY- Log delay zone closed ZONE 16.LOG 150
CUSTOM A- Zone closed(Non alarm) ZONE 16.LOG 150
CUSTOM B- Zone closed(Non alarm) ZONE 16.LOG 150
EXITGUARD- Exitguard zone closed ZONE 16.LOG 150
RD Prog, denied RMACCESS+ Zone denied rem. acc ZONE 14.MEN AC 553
RO Relay open BELL FAIL Bell fail zone opened ZONE 16. LOG 150
KEYSWITCH KS NONE 150
LINK+ Link zone opened ZONE 16.LOG 150
LOG+ Log zone opened ZONE 16.LOG 150
LOG DELAY+ Log delay zone opened ZONE 16.LOG 150
NOT USED ZONE 16. LOG 150
SET LOG ZONE 16. LOG 150
CUSTOM A+ Zone opend(Non alarm) ZONE 16.LOG 150
CUSTOM B+ Zone opend(Non alarm) ZONE 16.LOG 150
EXITGUARD+ Exitguard zone opened ZONE 16.LOG 150
PUSH SET Push set zone opened ZONE NONE 150
KSW RESET KS NONE 150
SPARE Spare zone opened ZONE 16. LOG 150
RP Automatic test AUTOTEST Automatic test EVENT ALWAYS TR 602
RR Power Up MEMORY OK Warm start of panel EVENT 13.ELEC ST 305
RS Prog, success RM ACCESS- Zone allowed rem acc ZONE 14.MEN AC 553
REM CALL Remote call complete MOD 14.MEN AC 412
RX Manual test ENG TEST Engineer test USER ALWAYS TR 601