GX-Series Control Panel Installation and Setup Guide
D-4
KEYPAD TEXT DESCRIPTION
TRIGGER
EVENT
PA PA zone activated (opened) 1. PA/Duress M
PA DEL/SL PA Delayed Silent zone activated (opened). 1. PA/Duress M
PA DELAY PA Delayed zone activated (opened). 1. PA/Duress M
PA RESET PA Reset has occurred. 1. PA/Duress NM
PA SILENT PA Silent zone activated (opened). 1. PA/Duress M
PA UNSET PA Unset zone activated while group in unset (disarmed) condition. 1. PA/Duress M
PART SET Part Set of system or Group(s). 10. Setting M
PF RESET System has returned to the set status after a power failure. 20. Fault NM
PREWARN System or Group(s) in the Autoset Prewarning period. None NM
PRINT OC Print On Command. None NM
PRINT OL Print On Line, the automatic printing of the Event Log. Not to be confused with
the printer on-line message from a printer.
None NM
+PRT ENTRY Part Entry zone activated (opened). 2. Intruder NM
–PRT ENTRY Part Entry zone de-activated (closed). 2. Intruder
18. Zone restoral
NM
+PRT FINAL Part Final zone activated (opened). 2. Intruder NM
–PRT FINAL Part Final zone de-activated (closed). 2. Intruder
18. Zone restoral
NM
+PSU FLT Power Supply Unit fault 13. Elec. Status
20. Fault
M
PUSH SET Push Set (Exit Terminator) zone activated (opened). None NM
R.TIMESET Remote timeset. None NM
REARM Rearm of system has occurred. 10. Setting M
RECEN.SET Recent Set. Alarm occured within 5 minutes of set. 2. Intruder M
REM ABORT Remote connection timeout. None NM
+REM CALL Remote device connected. 14. menu access NM
–REM CALL Remote device disconnected. 14. Menu access NM
REM COPY Remote Copy of site details via SIA has occurred. None NM
REM FAIL Remote failure after all retries. None NM
REM FIN Remote connection finished. None NM
REM ID Remote suite ID menu accessed. None NM
REM LOG Remote log menu accessed. None NM
REM MSG Remote message menu accessed. None NM
REM OVRWR Remote Overwrite via SIA has occurred. None M
REM RESET Remote reset menu accessed. None NM
REM TRY First remote connection attempt logged. None NM
REM WR/RD Diagnostics remote read/write None M
REMOVED Engineer has Removed a module from the system. 9. Tamper M
RF BATLOW RF Battery low 13. Elec. Status
15. Trouble
20. Fault
M
RF JAM RF signal jammed 15. Trouble
20. Fault
M
RF MEM! RF RIO Non Volatile Memory failed 9. Tamper M
RF SUPER RF Supervision failure 19. RF
Supervision 20.
Fault
M
RM ACCESS Remote Access zone activated 14. Menu Access NM
+SEC FINAL Security Final zone activated (opened) 4. Security M
-SEC FINAL Security Final zone closed (closed) 4. Security
18. Zone restoral
M
+SECURITY Security zone activated (opened). 4. Security M
–SECURITY Security zone de-activated (closed). 4. Security
18. Zone restoral
M
SET LOG Set Log zone activated (opened) when the system or group(s) is set. 16. Log zone M
SOAK TEST Zone under Soak Test (Menu Option 55) activated when the system or group(s)
is Set.
None NM
SPARE Spare zone opened. 16. Log zone M
STANDLOW Standby time for the battery is Low. 13. Elec status M
SUSP. SET Setting of system suspended None NM
SYS RESET System Reset has occurred event. 11. Reset/Cancel NM
TAG REJECTED Rejected card
TAG VALID Valid card
TAG HARD
ANTIPASSBACK
Hard APB
TAG SOFT
ANTIPASSBACK
Soft APB
TAG REJECT NOT
GRP MATCH
Rejected card - no group match