GX-Series Control Panel Installation and Setup Guide
6-30
NOTE: Only the engineer can enable early opening for individual groups, but global enable must be done first.
2 = Early Open
Type 3. 6 Users and Engineer when Groups are Disabled
If groups have not been enabled on the system, the programming of the Early Open option is identical for
type 3.6 users and the engineer; the option permits early opening to be disabled or enabled:
0 = Disabled (default) — early opening not permitted;
1 = Enabled — early opening permitted.
Select the required status and press the ent key to accept the programming and return to the previous
menu.
Engineer Mode with Groups Enabled
If groups have been enabled (option 63 = OPTIONS + early open permitted), then the groups can be
individually enabled to permit early opening.
45.4 = Timers
This option allows each of the programmed weekly timer schedules to be switched on and off as required. If a
timer schedule is set to off, the operation of the timer is suspended; this option cannot be used to alter the
programmed times. All timer schedules default to 0 = Off. To switch the timer schedule on, select the
required timer and change the setting to 1 =On.
The Timer Status can also be altered through menu option 65.1 by the engineer only.
On selecting the option, the early opening status of the groups is displayed; early opening enabled is
indicated by a Y below the group; an N is displayed below the groups that are not programmed to open early.
All groups default to N.
NOTE: Only the engineer can enable early opening for individual groups, but global enable must be done first.
45.5 = Late Work
The Late Work option — if programmed as 1 = Enabled — authorizes an Autoset Extension in advance
of the prewarning period (refer to option 65.3 = TIMERS.Autoset);
NOTE: Additional extensions can be authorized by entry of a valid code during the subsequent autoset
prewarning periods.
45.6 = Weekend Work
The Weekend Work option allows a valid user code to authorize the system to unset (disarm) at the
weekend. There are two options:
1 = Program Days
This option allows the weekend day option to be selected.
1 = Weekend Day
On selecting this option the programmed Weekend Day is displayed; the default is 0 = OFF. Use
the A> or <B keys to select the required day or days and press the ent key to accept the
programming and return to the previous menu level:
0 = OFF
1 = SAT
2 = SUN
3 = BOTH (Saturday and Sunday)
The selected Weekend Day remains active for one occurrence only. The Weekend Day returns to
the default of OFF immediately following the assigned day. The Weekend Day must be allocated
each time the function is required.
If the Weekend Day is programmed other than 0 = OFF (default), on the next occurrence of the
programmed Weekend Day, the Timers adopt the times assigned in Pattern day from option
65.1.6. For example, this allows a Sunday to use the Autoset and Lockout Timers from Monday to
Friday.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell GX-Series and is the answer not in the manual?

Honeywell GX-Series Specifications

General IconGeneral
BrandHoneywell
ModelGX-Series
CategoryControl Panel
LanguageEnglish

Related product manuals