Configuration
30 UDC2300 Controller Product Manual 12/00
Table 4-5 SPRAMP Group (Numeric Code 300) Function Prompts, continued
Prompt Selection or Range of Setting
English Numeric
Code
Description
Numeric
Code
English
Factory
Setting
Reference
Guide
Page
RPUNIT 310 Engineering
units for Ramp
Segments
0
1
2
TIME (hours:minutes)
EU-M (Rate EU/Minute)
EU-H (Rate EU/Hour)
TIME 150
RECYCL 311 Number of
Program
Recycles
0 to 99 recycles - - - 149
SOKDEV 312 Guaranteed
Soak Deviation
Value
0 to 99
0 = No Soak
- - - 152
PG END 313 Program
Termination
State
0
1
LAST (Hold at last SP)
FSAF (Manual
mode/failsafe)
- - - 145
STATE 314 Program State
at Program End
0
1
DIS
HOLD
DIS 155
ToBEGN 315 Reset Program
to the Beginning
0
1
DIS
KEY (Keyboard)
DIS 156
PVSTRT 316 Program starts
at PV value
0
1
DIS
ENAB
DIS
SGx RP
SG1
SG3
SG5
SG7
SG9
SG11
317
320
323
326
329
332
Segment Ramp
or Rate Time
x = 1 through 11
0-99hours:0-59minutes
Engineering Units/minute
or
Engineering Units /hour
- - - 151
SGx SP
SG2
SG4
SG6
SG8
SG10
SG12
318
321
324
327
330
333
Segment Soak
Setpoint Value
x = 2 through 12
Enter a Value within the
Setpoint Limits
- - - 151
SGx TI
SG2
SG4
SG6
SG8
SG10
SG12
319
322
325
328
331
334
Segment Soak
Duration
x = 2 through 12
0-99 Hours:0-59 Minutes - - - 152