Table 5-4 QuickFind Diagnostic Panel LED Definitions (continued)
DetailsLED3LED 2LED 1LED 0Item
One of the power supply or power supply fans
have failed. Replace the power supply. The faulty
power supply LED (located on power supply) is
lit.
n/an/an/aCheck Power
Supply
The DIMMs in a rank are mismatched. All the
DIMMs in the specified rank (0-7) are lit.
n/an/an/aMemory
Config Error
The processors are mismatched. Replace
mismatched processor.
n/an/an/aProcessor
Config Error
A required component(s) is not installed in the
server and thus preventing “power-on.”
n/an/an/aMissing
Component
The internal temperature of the server has
exceeded the warning or critical level.
n/an/an/aServer Temp
An event occurred that requires attention.n/an/an/aCheck Event
Log
I/O Baseboard LED Indicators
Figure 5-5 shows the various LEDs, sensors, and reset or attention buttons found on the I/O
baseboard. Table 5-5 describes the status of the various LEDs on the I/O baseboard.
102 Troubleshooting

Table of Contents

Other manuals for HP Integrity rx4640

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP Integrity rx4640 and is the answer not in the manual?

HP Integrity rx4640 Specifications

General IconGeneral
BrandHP
ModelIntegrity rx4640
CategoryServer
LanguageEnglish

Related product manuals