To replace the component, reverse the removal procedure.
Removing and replacing the access panel
CAUTION: Do not operate the server for long periods with the access panel open or removed. Operating the server
in this manner results in improper airflow and improper cooling that can lead to thermal damage.
Prerequisites
Before you perform this procedure, make sure that you have a T-15 Torx screwdriver available.
Procedure
1.
If installed, remove the bezel.
2.
Power down the server.
3.
Remove all power:
a.
Disconnect each power cord from the power source.
b.
Disconnect each power cord from the server.
4. Disconnect all peripheral cables from the server.
5.
Remove the server from the rack.
6. Remove the access panel:
a. If necessary, unlock the access panel latch.
b. To disengage the access panel from the chassis, press the release button and pull up the latch.
c. Lift the access panel.