a. Remove screws.
b. Detach the ambient thermal sensor cable from its clip.
c. Remove the front I/O module.
To replace the component, reverse the removal procedure.
Removing and replacing the SFF front I/O assembly
Prerequisites
Before you perform this procedure, make sure that you have the following tools available.
• T-10 screwdriver
• T-15 screwdriver
Procedure
1.
If installed, remove the bezel.
2.
Power down the server.
3. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
4. Disconnect all peripheral cables from the server.
5.
Remove the server from the rack.
6. Remove the inner rack rails.
7. Remove the access panel.