Procedure
1. If installed, remove the bezel.
2. Power down the server.
3. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
4. Disconnect all peripheral cables from the server.
5.
Remove the server from the rack.
6.
Remove the access panel.
7. Remove the primary riser cage.
8. Remove the OCP NIC
30 adapter.
a. Lift the locking pin that secures the adapter to the slot.
b.
Slide the OCP NIC 30 adapter out of the slot.
c.
Close the locking pin
To replace the component, reverse the removal procedure.
Removing and replacing the OCP NIC 3.0 adapter rails
WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the internal system
components to cool before touching them.
CAUTION: Electrostatic discharge (ESD) can damage electronic components. Be sure that you are properly
grounded (earthed) before beginning any installation procedure.