Loading...
Removing a Fibre Channel SFP
Procedure
1. Disconnect the FC cable from the SFP.
2. Lift the retaining clip and carefully slide the SFP out of the enclosure.
Installing a Fibre Channel SFP
Procedure
1. Remove the replacement SFP module from its protective packaging.
CAUTION:
When handling the SFP, do not touch the gold contact leads to prevent damage.
2. Carefully slide the replacement SFP into the enclosure until fully seated.
3. Close the retaining clip to secure it in place.
4. Place the failed SFP into the packaging for return to Hewlett Packard Enterprise.
Verifying Fibre Channel SFP operation
Procedure
Reconnect the FC cable to the SFP and verify that the link status LED is solid green. For more
information, see "Related reference".
More information
Status LED descriptions on page 15
Removing and replacing the fan control card cable
assembly
CAUTION:
This procedure requires removing the enclosure from the rack. Before removing the enclosure,
ensure that data on the system is backed up. Back up data if necessary.