• Two for the 10 GbE/10GBase-T network on Controller 1
• Two for the 10 GbE/10GBase-T network on Controller 2
• One for the VIP
• All other interfaces are disabled
The following figure illustrates the cabling described.
Figure 18: Configuration using four 10 GbE / 10GBase-T ports and two switches
1. Servers 2. 10 GbE/ 10GBase-T iSCSI SAN
3. Network cloud connections 4. StoreVirtual storage system
Network configuration for array enclosure with Fibre Channel controller
modules (two ports)
The two Fibre Channel ports on each controller are used for data connections. The two 1 GbE ports can
be used for Management and Remote Copy. The 1 GbE ports are bonded together for redundancy and
performance during the Configuration Setup procedure.
Physical connections:
• Connect FC-1 and FC-2 on each controller to a switch (four Fibre Channel connections).
• Connect 1G-1 and 1G-2 on each controller to a switch (four 1 GbE connections).
Required IP addresses:
40 Network configuration for array enclosure with Fibre Channel controller modules (two ports)