EasyManua.ls Logo

Huawei 5288 V3 V100R003 - Page 138

Huawei 5288 V3 V100R003
297 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Table 7-1 Mapping
Hard Disk Position Panel Silkscreen Slot ID
Front hard disks 0 to 23 DISK0 to DISK23
Rear hard disks
l With one RAID
controller card: 24 to 35
l With two RAID
controller cards: 0 to 11
l With one RAID
controller card: DISK24
to DISK35
l With two RAID
controller cards: DISK0
to DISK11
Rear hard disks HDD A0, HDD B0, HDD
A1, and HDD B1
DISKA, DISKB, DISKC,
and DISKD
Procedure
Step 1 Wear an ESD wrist strap. For details, see 1 Safety Instructions.
Step 2 Determine the rack number and chassis number of the server to be removed, and label its
panel to prevent misoperations.
Step 3 If a front hard disk needs to be removed and the server is equipped with a front bezel, remove
the bezel. For details, see 7.3 (Optional) Removing the Front Bezel.
Step 4 Determine the position of the hard disk (for example, a front hard disk) on the 5288 V3. See
Figure 7-10.
Figure 7-10 Hard disk position
5288 V3 Server
User Guide
7 Replacing Parts
Issue 26 (2018-11-19) Copyright © Huawei Technologies Co., Ltd. 128

Table of Contents

Related product manuals