The system view is displayed.
2. Run:
isis [ process-id ]
The IS-IS view is displayed.
3. Run:
circuit-cost cost [ level-1 | level-2 ]
The global IS-IS cost is configured.
You can use the circuit-cost command to configure the costs of all interfaces at a time.
l Enable IS-IS to automatically calculate interface costs.
1. Run:
system-view
The system view is displayed.
2. Run:
isis [ process-id ]
The IS-IS view is displayed.
3. Run:
bandwidth-reference value
The reference value of the bandwidth is configured. By default, the bandwidth
reference value is 100 Mbit/s.
4. Run:
auto-cost enable
The interface is configured to automatically calculate its cost.
The configuration of the bandwidth reference value takes effect only when the cost type is
wide or wide-compatible. In this case, Cost of each interface = (Value of bandwidth-
reference/Interface bandwidth) x 10.
If the cost-style is narrow, narrow-compatible, or compatible, the cost of each interface is
based on costs listed in Table 6-1.
Table 6-1 Mapping between IS-IS interface costs and interface bandwidth
Cost
Bandwidth Range
60
Interface bandwidth 10 Mbit/s
50
10 Mbit/s < interface bandwidth 100 Mbit/
s
40
100 Mbit/s < interface bandwidth 155 Mbit/
s
30
155 Mbit/s < interface bandwidth 622 Mbit/
s
20
622 Mbit/s < Interface bandwidth 2.5 Gbit/
s
S6700 Series Ethernet Switches
Configuration Guide - IP Routing 6 IS-IS Configuration
Issue 01 (2012-03-15) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
249

Table of Contents

Other manuals for Huawei S1720 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei S1720 Series and is the answer not in the manual?

Huawei S1720 Series Specifications

General IconGeneral
Operating Humidity5% to 95% (non-condensing)
Uplink Ports4 x GE combo ports
VLANs4094
Power SupplyAC 100-240V, 50/60Hz
Layer 2 FeaturesVLAN
Layer 3 FeaturesStatic routing
ManagementSNMP
Operating Temperature0°C to 45°C
Storage Temperature-40°C to +70°C
Dimensions (W x D x H)442 mm x 220 mm x 43.6 mm