8. Parameter
Fieldbus Communication
194
RCP6
S
[6] Default velocity (Parameter No.8)
No. Name Symbol Unit Input Range
Default factory
setting
8 Default Velocity VCMD
mm/s
[deg/s]
1 to Actuator’s
max. speed
Rated actuator
speed
The factory setting is the rated velocity of the actuator.
When a target position is set in an unregistered position table, the setting in this parameter is
automatically written in the applicable position number.
It is convenient to set the velocity often used.
[7] Default acceleration/deceleration (Parameter No.9)
No. Name Symbol Unit Input Range
Default factory
setting
9 Default Acceleration/Deceleration ACMD G
0.01 to Actuator's
max. acceleration/
deceleration
Rated actuator's
acceleration/
deceleration
The factory setting is the rated acceleration/deceleration of the actuator.
When a target position is set in an unregistered position table, the setting in this parameter is
automatically written in the applicable position number.
It is convenient to set the acceleration/deceleration often used.
[8] Default positioning width (in-position) (Parameter No.10)
No. Name Symbol Unit Input Range
Default factory
setting
10 Default Positioning Width INP
mm
[deg]
Actuator's min.
resolution to 999.99
In accordance
with actuator
When a target position is set in an unregistered position table, the setting in this parameter is
automatically written in the applicable position number. When the remaining moving distance
enters into this width, the positioning complete signal PEND/INP is output.
It is convenient to set the positioning width often used.
[9] Current-limiting value at standstill during positioning (Parameter No.12)
No. Name Symbol Unit Input Range
Default factory
setting
12
Current-limiting value at standstill
during positioning
SPOW % 0 to 70
In accordance
with actuator
When the value is increased, the stop holding torque is increased.
Even though it is generally unnecessary to change this setting, setting the value larger is
necessary in the case a large external force is applied during stop. Please contact IAI.
For RCP6S and RCM-P6PC only
ME0349-4B

Table of Contents

Other manuals for IAI RCP6S

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IAI RCP6S and is the answer not in the manual?

IAI RCP6S Specifications

General IconGeneral
BrandIAI
ModelRCP6S
CategoryConference System
LanguageEnglish

Related product manuals