Page #182 background image
Table 16. Troubleshooting (continued)
Problem indicator Component Possible cause Possible solutions
Amber and green
LEDs are lit
Power supply
(Amber fault
LED is lit and
both power
LEDs are not
lit, AC power
or DC IN LED
is lit and DC
power or DC
out LED is not
lit)
Power supply
failure
Replace the failed power supply.
See Chapter 5, “Replacing
components,” on page 105 for
more information.
All amber and
green LEDs are
slowly flashing
All drives
(activity and
fault LEDs are
not lit)
Check for and solve one of the following situations:
v storage enclosures are not correctly connected to the
DS3500.
v DS3500 does not have the correct firmware version.
All green LEDs
are off
All components Subsystem power is
off
Ensure that all storage subsystem
power cables are connected and
that the power-supply switches
are on. If applicable, ensure that
the main circuit breakers for the
rack are turned on.
Power failure Check the main circuit breaker
and ac receptacle (ac models).
Check the -48 V dc power source
and disconnect device (dc
models).
Power-supply
failure
Replace the power supply.
Operating
environment is too
hot
Cool down the environment.
Amber LED is
flashing
Drives (fault
LED is lit)
Drive identification
is in process
No corrective action is needed.
164 IBM System Storage DS3500 and EXP3500 Storage Subsystem: Installation, User's, and Maintenance Guide

Table of Contents

Other manuals for IBM DS3500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM DS3500 and is the answer not in the manual?

IBM DS3500 Specifications

General IconGeneral
Storage TypeDisk Array
Form Factor2U
Supported DrivesSAS, SATA
RAID Levels0, 1, 5, 6, 10, 50, 60
Management SoftwareIBM System Storage DS Storage Manager
Operating System SupportWindows, Linux, VMware, AIX, HP-UX, Solaris
ModelIBM DS3500
Host InterfacesSAS
Cache Memory2 GB
Power SupplyDual redundant, hot-swappable
Number of Controllers2