Step 1522-15
Note: Read the danger and caution notices under “Safety Notices” on page xi before continuing with this
procedure.
Perform the following:
1. Disconnect the ac power cable(s) from the power distribution unit that supplies power to the I/O
drawer.
2. Use a multimeter to measure the ac voltage at the power distribution unit socket(s) where the ac
power cable(s), just removed, was (were) attached.
Is the ac voltage from 200 V ac to 240 V ac?
NO Replace the power distribution unit
This ends the procedure. Go to MAP 0410: Repair Checkout in the RS/6000 Eserver pSeries
Diagnostic Information for Multiple Bus Systems.
YES Go to “Step 1522-16”.
Step 1522-16
Reconnect the ac power cable(s) to the power distribution unit.
Note: Read the danger and caution notices under “Safety Notices” on page xi before continuing with this
procedure.
Perform the following:
1. Disconnect the ac power cable from each power supply of the I/O drawer.
2. Use a multimeter to measure the ac voltage at the drawer end of each ac power cable.
Is the ac voltage from 200 V ac to 240 V ac?
NO Replace the ac power cable(s).
This ends the procedure. Go to MAP 0410: Repair Checkout in the RS/6000 Eserver pSeries
Diagnostic Information for Multiple Bus Systems.
YES Go to “Step 1522-17”.
Step 1522-17
Replace the following in the I/O drawer, one at a time, disconnecting the ac power cable (dc power cable
for a dc-powered system) to each power supply before replacement and reconnecting the ac power cable
(dc power cable for a dc-powered system) to each supply after replacement:
v I/O power supply 1.
v I/O power supply 2.
v I/O drawer backplane
Does the operator panel show the OK prompt?
NO Contact your next level of support for assistance.
YES This ends the procedure. Go to MAP 0410: Repair Checkout in the RS/6000 Eserver pSeries
Diagnostic Information for Multiple Bus Systems.
Chapter 3. Maintenance Analysis Procedures (MAPs) 117

Table of Contents

Other manuals for IBM pSeries 630 6C4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM pSeries 630 6C4 and is the answer not in the manual?

IBM pSeries 630 6C4 Specifications

General IconGeneral
BrandIBM
ModelpSeries 630 6C4
CategoryServer
LanguageEnglish

Related product manuals