Step 1522-18
Is the ac power cable from the rack power distribution unit to the customer’s ac power outlet
connected and seated correctly at both ends?
NO Connect the ac power cable correctly at both ends.
This ends the procedure. Go to MAP 0410: Repair Checkout in the RS/6000 Eserver pSeries
Diagnostic Information for Multiple Bus Systems.
YES Go to “Step 1522-19”.
Step 1522-19
Note: Read the danger and caution notices under “Safety Notices” on page xi before continuing with this
procedure.
Perform the following:
1. Disconnect the mainline ac power cable from the power distribution unit that supplies power to the I/O
drawer.
2. Use a multimeter to measure the ac voltage at the power distribution unit end of the mainline ac power
cable.
Is the ac voltage from 200 V ac to 240 V ac?
NO Go to “Step 1522-20”.
YES Replace the power distribution unit.
This ends the procedure. Go to MAP 0410: Repair Checkout in the RS/6000 Eserver pSeries
Diagnostic Information for Multiple Bus Systems.
Step 1522-20
Note: Read the danger and caution notices under “Safety Notices” on page xi before continuing with this
procedure.
Perform the following:
1. Disconnect the mainline ac power cable from the customer’s ac power outlet.
2. Use a multimeter to measure the ac voltage at the customer’s ac power outlet.
Is the ac voltage from 200 V ac to 240 V ac?
NO Inform the customer that the ac voltage at the power outlet is not correct.
This ends the procedure. Go to MAP 0410: Repair Checkout in the RS/6000 Eserver pSeries
Diagnostic Information for Multiple Bus Systems.
YES Replace the mainline ac power cable.
This ends the procedure. Go to MAP 0410: Repair Checkout in the RS/6000 Eserver pSeries
Diagnostic Information for Multiple Bus Systems.
Step 1522-21
Are the amber fault LEDs of both power supplies of the I/O drawer on solid?
NO Go to “Step 1522-22” on page 119.
YES Go to “Step 1522- 25” on page 119.
118 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide

Table of Contents

Other manuals for IBM pSeries 630 6C4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM pSeries 630 6C4 and is the answer not in the manual?

IBM pSeries 630 6C4 Specifications

General IconGeneral
BrandIBM
ModelpSeries 630 6C4
CategoryServer
LanguageEnglish

Related product manuals