Checkpoint Description Action/
Possible Failing FRU
E1F9 Building boot device list for fibre-channel
adapters. (The location of the SAN adapter
being scanned is also displayed.)
1. If a location code is available, follow the
Repair actions listed for error code
21A0 00XX.
2. If no location code is available, go to
“MAP 1540: Problem Isolation
Procedures” on page 124.
E1FA Building boot device list for SCSI adapters.
(The device ID and the device LUN being
scanned are also displayed.)
Go to “MAP 1540: Problem Isolation
Procedures” on page 124.
E1FB Scan SCSI bus for attached devices
1. If a location code is available, follow the
Repair actions listed for error code
21A0 00XX.
2. If no location code is available, go to
“MAP 1540: Problem Isolation
Procedures” on page 124.
E1FC Building boot device list for SSA adapters.
(The location code of the SSA adapter
being scanned is also displayed.)
Go to “MAP 1542: I/O Problem Isolation” on
page 127.
E1FD The operator panel alternates between the
code E1FD and another Exxx code, where
Exxx is the point at which the error
occurred.
1. If a location code is available, follow the
actions listed for error code 21A0 00xx.
2. If no location code is available, go to
“MAP 1540: Problem Isolation
Procedures” on page 124.
E1FE Building boot device list for fibre-channel
adapters. (The WWPN of the SAN adapter
being scanned is also displayed.)
1. If a location code is available, follow the
Repair actions listed for error code
21A0 00XX.
2. If no location code is available, go to
“MAP 1540: Problem Isolation
Procedures” on page 124.
E1FF Building boot device list for fibre-channel
adapters. (The WWPN of the SAN adapter
being scanned is also displayed.)
Go to “MAP 1542: I/O Problem Isolation” on
page 127.
E20F System firmware has exited to open
firmware prompt
1. Replace the CEC backplane,
Location: U0.1-P1.
2. Call service support.
E440 Validate NVRAM, initialize partitions as
needed
1. Check for system firmware updates.
2. Replace the CEC backplane,
Location: U0.1-P1.
3. Call service support.
E441 Generate /options node NVRAM
configuration variable properties
1. Check for system firmware updates.
2. Replace the CEC backplane,
Location: U0.1-P1.
3. Call service support.
E442 Validate NVRAM partitions
1. Check for system firmware updates.
2. Replace the CEC backplane,
Location: U0.1-P1.
3. Call service support.
E443 Generate NVRAM configuration variable
dictionary words
Suspect a system firmware problem if
problem persists. If a system firmware
update is available, install it.
174 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide