Table 3. SPCN Error Codes for I/O Subsystems
Error Code Description Action/
Possible Failing FRU
1nn1 00AC AC loss or brownout detected Informational message.
1nn1 00EF Remote emergency power off occurred Informational message.
1nn1 1510 Power supply 1 source failure
1. Check the input voltage to the power supply.
2. I/O subsystem power supply 1, U0.dd-V1.
3. I/O subsystem backplane, U0.dd-P1.
1nn1 1511 Power supply 1 fault
1. I/O subsystem power supply 1, U0.dd-V1.
2. I/O subsystem backplane, U0.dd-P1.
1nn1 1512 Power supply 1 non-power fault
1. I/O subsystem power supply 1, U0.dd-V1.
2. I/O subsystem backplane, U0.dd-P1.
1nn1 1513 Power supply 1 domain fault
1. I/O subsystem power supply 1, U0.dd-V1.
2. I/O subsystem backplane, U0.dd-P1.
1nn1 1517 Power supply 1 thermal fault
1. Check for obstructions to the air flow around
the I/O subsystem.
2. I/O subsystem power supply 1, U0.dd-V1.
3. I/O subsystem backplane, U0.dd-P1.
1nn1 1520 Power supply 2 source failure
1. Check the input voltage to the power supply.
2. I/O subsystem power supply 2, U0.dd-V2.
3. I/O subsystem backplane, U0.dd-P1.
1nn1 1521 Power supply 2 fault
1. I/O subsystem power supply 2, U0.dd-V2.
2. I/O subsystem backplane, U0.dd-P1.
1nn1 1522 Power supply 2 non-power fault
1. I/O subsystem power supply 2, U0.dd-V2.
2. I/O subsystem backplane, U0.dd-P1.
1nn1 1523 Power supply 2 domain fault
1. I/O subsystem power supply 2, U0.dd-V2.
2. I/O subsystem backplane, U0.dd-P1.
1nn1 1527 Power supply 2 thermal fault
1. Check for obstructions to the air flow around
the I/O subsystem.
2. I/O subsystem power supply 2, U0.dd-V2.
3. I/O subsystem backplane, U0.dd-P1.
1nn1 1B01 +12 V load fault
1. Replace power supply 1, U0.dd-V1.
2. If power supply 2 is present, use power
supply 1 that was removed to replace power
supply 2.
3. I/O subsystem backplane, U0.dd-P1.
1nn1 1B02 +5 V load fault
1. Replace power supply 1, U0.dd-V1.
2. If power supply 2 is present, use power
supply 1 that was removed to replace power
supply 2.
3. I/O subsystem backplane, U0.dd-P1.
Chapter 5. Error Code to FRU Index 223

Table of Contents

Other manuals for IBM pSeries 630 6C4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM pSeries 630 6C4 and is the answer not in the manual?

IBM pSeries 630 6C4 Specifications

General IconGeneral
BrandIBM
ModelpSeries 630 6C4
CategoryServer
LanguageEnglish

Related product manuals