LED Status Description
Green All diagnostics pass. The
module is operational (normal
initialization sequence).
Red Indicates one of the following:
The diagnostic test has failed.
The module is not operational
because a fault has occurred
during the initialization sequence.
The inlet air temperature of the
system has exceeded the safe
operating temperature limits of
the card (a major environmental
warning). The card has been
shut down to prevent permanent
damage.
Blinking Red Indicates one of the following:
The fabric module has just been
inserted and is booting up.
An over temperature condition
has occurred and the module has
powered down.
The power was turned off with a
CLI command.
1. The module is resetting and
both ejector levers are out.
Status
Off The module is not receiving
power.
Blinking Blue The operator has activated this
LED to identify this module in the
chassis.
Locator ID
Off Operator has not flagged this
card for identification.
Table 6. SAN768C-6 Crossbar Modules LEDs
SAN384C-6 Crossbar Fabric Modules
The SAN384C-6supports up to six crossbar (xbar) fabric switching modules. The Crossbar Fabric-1 and
Crossbar Fabric-3 switching modules are supported. The crossbar fabric switching modules are installed
vertically at the back of the chassis behind the fan modules.
Crossbar fabric switching module slots 1 and 2 are behind the fan module slot 1, the crossbar fabric
switching module slots 3 and 4 are behind the fan module slot 2, and crossbar fabric switching module
slots 5 and 6 are behind the fan module slot 3.
26IBM Storage Networking SAN192C-6, SAN384C-6 and SAN768C-6: SAN192C-6, SAN384C-6 and