Figure 70. Drive assembly
1 Disk drive
2 Online indicator
3 Fault indicator
4 Release latch
5 Drive latch toes
6 Drive carrier
Procedure
1. Read all of the available safety information.
2. Remove the cover, as described in “Removing the top cover: 2076-92F ” on page 46.
3. Locate the empty drive slot to receive the new drive or that contains the faulty drive that you want to
replace.
Note: When a drive is faulty, the amber fault indicator is lit ( 3 in Figure 70 on page 64). Do not
replace a drive unless the drive fault indicator is on or you are instructed to do so by a x procedure.
A label on the enclosure cover (Figure 71 on page 64) shows the drive locations in the enclosure.
The drive slots are numbered 1-14 from left to right and A-G from the back to the front of the
enclosure.
Figure 71. Drive locations in a 5U expansion enclosure
The drive slots must be populated sequentially, starting from the back-left corner position (slot 1,
grid A1). Sequentially install the drive in the slots from left to right and back row to front. Always
complete a full row before you install drives in the next row. For example, in Figure 72 on page 65,
the drives are installed correctly. Drives are installed in slots 1 -14 of row A and the installation
continues in slot 15 in row B.
64
Storwize V7000 : Gen3 Quick Installation Guide for MTM 2076-724, 2076-U7B, 2076-12F, 2076-24F, and
2076-92F