Important: If you do not perform library shutdown before you power off the
library, loss of data could occur.
Restart shuts down and restarts the library’s operating system and firmware.
When performing a restart, the library finishes all active commands received from
the host application and does not process any new commands. The library shuts
down all logical libraries and restarts them during the reboot. In addition, the
library performs an inventory of cartridges, tape drives, and slots during a reboot.
Shutting Down the Library
Servicing some components requires only that you take the library offline, while
servicing other components requires that you power OFF the entire library. For
details, see “Required Library State” on page 11-1. When library power is switched
OFF, the Picker assembly slowly falls to rest at the bottom of the library.
Important: To completely remove all power before servicing or in an emergency,
push the front power button, toggle the power switch on each power
supply to the OFF (O) position, and disconnect all power cords from
their electrical source.
1. Using the library’s Operator Panel, ensure that no applications are accessing the
library. If a Progress Screen is open, wait until the operation completes.
2. Take the entire library (including all drives and logical libraries) offline.
v To take each logical library offline using the Operator Panel, select
Operations Change Logical Library Mode.
v To take each drive offline using the Operator Panel, select Operations
Change Drive Mode.
3.
Shut down the library from the Operator Panel by selecting Operations
Shutdown. The System Shutdown window appears.
4. In the System Shutdown window, select Shutdown and click Apply.
5. In the System Shutdown Confirmation window, click Yes.
6. Press the power button located on the front of the control module.
7. Toggle the power switch on each power supply to the OFF (O) position.
8. Disconnect the library’s power cords from their electrical source.
Restarting the Library
1. Using the library’s Operator Panel, ensure that no applications are accessing the
library. If a Progress Screen is open, wait until it closes before attempting to
restart the library.
2. Take the entire library (including all drives and logical libraries) offline.
v To take each logical library offline using the Operator Panel, select
Operations Change Logical Library Mode.
v To take each drive offline using the Operator Panel, select Operations
Change Drive Mode.
3.
From the Operations menu, click Restart. The System Shutdown window
appears.
4. In the System Shutdown window, select Restart and click Apply.
5. In the System Restart Confirmation window, click Yes.
6. Bring the entire library (including all drives and logical libraries) online.
v Bring the desired logical libraries back online using the Operator Panel by
selecting Operations Logical Library Mode.