Root Causes Drive has determined that there is a problem per its
internal algorithms.
Possible CRU Replacements Tape Cartridge
Resolution If the cartridge is manage by a host application, export the
cartridge via the host application.
If the cartridge is managed by the library, perform the
following:
v Remove the suspect cartridge (see “Exporting a Data
Cartridge” on page 7-15 or “Exporting a Cleaning
Cartridge” on page 7-16).
v Import a new cartridge (see “Importing Data Cartridges”
on page 7-15 or “Importing a Cleaning Cartridge” on
page 7-16).
T045: Drive TapeAlert Flag 20- Clean Now
Description System determines that the drive has issued a TapeAlert 20
indicating that the drive requires cleaning. This should be
coincident with a Bang C on the drive seven segment
display.
Detection Scenarios Tape drive issues a TapeAlert 20 which is recognized by
the library during the continuous four second polling cycle
of drive status.
Root Causes Drive has determined that there is a problem per its
internal algorithms.
Possible CRU Replacements
v Tape Drive
v Tape Cartridge
Resolution Perform “DR018: Manually Clean Drive” on page 10-35.
T046: Drive TapeAlert Flag 21 - Clean Periodic
Description System determines that the drive has issued a TapeAlert 21
indicating that the drive requires cleaning. This should be
coincident with a Bang C on the drive seven segment
display.
Detection Scenarios Tape drive issues a TapeAlert 21 which is recognized by
the library during the continuous four second polling cycle
of drive status.
Root Causes Drive has determined that there is a problem per its
internal algorithms.
Possible CRU Replacements
v Tape Drive
v Tape Cartridge
Resolution Perform “DR018: Manually Clean Drive” on page 10-35.
T047: Drive TapeAlert Flag 22 - Expired Cleaning Media
Description System determines that a cleaning media is expired.
Chapter 10. Service Action Tickets (Txxx) and Diagnostic Resolutions (DRxxx) 10-19