Table C-1. Library Sense Data and associated ASC/ASCQs (continued)
Sense
Key ASC ASCQ Description Required Action
2 04h 01h The library is becoming ready. Not Ready - Becoming Ready.
The drive has not finished the load and
thread operation yet.
Failure Isolation Procedure
No repair action required.
2 04h 03h The library is not ready and a manual
intervention is required.
**Not Ready - Manual Intervention
Required.
Failure Isolation Procedure
Check the library Operator Panel to ensure
that the library is not in offline, setup, or
maintenance mode. Check front doors to
ensure that they are all closed. Ensure that
power is on each of the installed drives.
Possible failure of a door switch.
FRU/CRU List
See “Contacting IBM Technical Support” on
page 9-15.
2 04h 83h The library is not ready due to aisle
power being disabled.
**Not Ready - Library Has Not Been Set
Up.
Library needs configuration and/or
calibration.
Check the Spooler Cable connection.
Failure Isolation Procedure
Have your customer run Library
Configuration (select Reports->Library
Configuration)
FRU/CRU List
See “Contacting IBM Technical Support” on
page 9-15.
2 04h 8Dh The library is not ready, because it is
offline.
**Library is Offline.
Failure Isolation Procedure
Check the library Operator Panel to ensure
that the library is not in offline, setup, or
maintenance mode.
B 08h 80h LU Communication - SCSI Failure
B 08h 82h LU Communication - SCSI Command
Execution or Queuing Failure
B 08h 83h LU - SCSI Command Failed
B 08h 84h LU Communication - SCSI Time-Out
B 08h 85h LU Communication - SCSI Autosense
Failed