v Check that the leader pin is properly seated (see 2 in Figure 8-8 on page 8-11).
v If you suspect that the cartridge has been mishandled but it appears usable,
discard the mishandled cartridge.
Examples of Cartridge Problems
Example: Split Cartridge Case (see “Perform a Thorough Inspection” on page
8-9)
The cartridge’s case is damaged. There is a high possibility of media damage and
potential loss. Perform the following steps:
1. Look for cartridge mishandling.
2. Use the IBM Leader Pin Reattachment Kit (part number 08L9129) to correctly
seat the pin (see “Repositioning a Leader Pin” on page 8-11). Then,
immediately use data recovery procedures to minimize chances of data loss.
3. Review media-handling procedures.
Example: Improper Placement of Leader Pin (see Figure 8-8 on page 8-11)
The leader pin is misaligned. Perform the following steps:
1. Look for cartridge damage.
2. Use the IBM Leader Pin Reattachment Kit (part number 08L9129) to correctly
seat the pin. Then, immediately use data recovery procedures to minimize
chances of data loss.
Repositioning or Reattaching a Leader Pin
Attention: Use a repaired tape cartridge only to recover and move data to
another cartridge. Continued use of a repaired cartridge may void the warranties
of the drive and the cartridge.
Figure 8-7. Checking for gaps in the seams of a cartridge
8-10 TS3310 Tape Library Setup and Operator Guide