Possible CRU Replacements
v Tape Cartridge
v Drive Sled
Resolution From the Operator Panel, select Tools → Service → Drive to
run the drive diagnostic. A blank, scratch cartridge is
required for this test.Before performing the following:
v “Removing a Drive Sled” on page 11-9
v “Replacing a Drive” on page 11-10
refer
to “Diagnosing a Problem” on page 9-3 for additional
diagnostic procedures.
T050: Drive TapeAlert Flag 31 - Hardware B
Description System determines that the drive has issued a TapeAlert 31
indicating a hardware error that requires a drive power
cycle before the drive might recover to a usable state.
Detection Scenario Tape drive issues a TapeAlert 31 which is recognized by
the library during the continuous four second polling cycle
of drive status.
Root Causes Drive has determined that there is a problem per its
internal algorithms.
Possible CRU Replacements
v Tape Cartridge
v Drive Sled
Resolution Before performing the following:
v “Removing a Drive Sled” on page 11-9
v “Replacing a Drive” on page 11-10
refer
to “Diagnosing a Problem” on page 9-3 for additional
diagnostic procedures.
T051: Drive TapeAlert Flag 32 - Interface
Description System determines that the drive has issued a TapeAlert 32
indicating a tape drive has detected a problem with the
application client interface.
Detection Scenarios Tape drive issues a TapeAlert 32 which is recognized by
the library during the continuous four second polling cycle
of drive status.
Root Causes Drive has determined that there is a problem per its
internal algorithms.
Possible CRU Replacements Tape Drive
Resolution Perform “DR012: Host Cabling Diagnostic” on page 10-34.
T052: Drive TapeAlert Flag 33 - Eject media error recovery
Description System determines that the drive has issued a TapeAlert 33
indicating that the drive requires a cartridge to be ejected
in order to resolve a problem.
Chapter 10. Service Action Tickets (Txxx) and Diagnostic Resolutions (DRxxx) 10-21