I.580A6 [I.580A6] Memory spare copy has completed successfully.
Explanation: Spare Copy Complete
Severity: Info
User response: Complete the following steps:
1. Check system log for related DIMM failures and replace those DIMMs.
S.1100B [S.1100B] CATERR(IERR) has asserted on processor %.
Explanation: Processor CATERR(IERR) has asserted
Severity: Error
User response: Complete the following steps:
1. Check IBM support site for an applicable service bulletin or firmware update that applies to this Processor error.
2. (Trained Service technician only) Replace the Processor. Inspect Processor socket and replace the system board
first if socket is damaged.
S.1100C [S.1100C] An uncorrectable error has been detected on processor %.
Explanation: Uncorrectable processor error detected
Severity: Error
User response: Complete the following steps:
1. Check IBM support site for an applicable service bulletin or firmware update that applies to this error.
2. Reboot system.
3. (Trained Service technician only) Replace the Processor. Inspect Processor socket and replace the system board
first if socket is damaged.
S.2011001 [S.2011001] An Uncorrected PCIe Error has Occurred at Bus % Device % Function %. The Vendor ID
for the device is % and the Device ID is %.
Explanation: PCI SERR Detected
Severity: Error
User response: Complete the following steps:
1. If this node and/or any attached cables were recently installed, moved, serviced or upgraded, a. Reseat Adapter
and any attached cables. b. Reload the latest Device Driver c. If device is not recognized, reconfiguring slot to
Gen1 or Gen2 may be required. Gen1/Gen2 settings can be configured via F1 Setup -> System Settings -> Devices
and I/O Ports -> PCIe Gen1/Gen2/Gen3 Speed Selection, or the ASU Utility.
2. Check IBM support site for an applicable device driver, firmware update, revision of service information for this
product or other information that applies to this error. Load new device driver and any required firmware
updates.
3. If problem persists, then remove Adapter Card. If system reboots successfully without the adapter, replace that
card.
4. (Trained Service technician only) Replace the processor.
5. (Trained Service technician only) Replace the system board.
I.580A6 S.2011001
598
System x3650 M4 BD Type 5466: Installation and Service Guide

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System x3650 M4 BD Type 5466 and is the answer not in the manual?

IBM System x3650 M4 BD Type 5466 Specifications

General IconGeneral
Form Factor2U Rack
Operating System SupportMicrosoft Windows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server, VMware vSphere
MemoryUp to 768GB DDR3
StorageUp to 16x 2.5" hot-swap SAS/SATA HDDs/SSDs
Power Supply750W
Network InterfaceIntegrated quad-port Gigabit Ethernet
RAID SupportRAID 0, 1, 10
Remote ManagementIBM IMM2
ProcessorIntel Xeon E5-2600 v2 series

Related product manuals