S.68005 [S.68005] An error has been detected by the the IIO core logic on Bus %. The Global Fatal Error
Status register contains %. The Global Non-Fatal Error Status register contains %. Please check error
logs for the presence of additional downstream device error data.
Explanation: Critical IOH-PCI Error
Severity: Error
User response: Complete the following steps:
1. Check log for a separate error for an associated PCIe device and service that error.
2. Check IBM support site for an applicable service bulletin or firmware update for the system or adapter that
applies to this error.
3. (Trained Service technician only) Replace the system board.
S.680B8 [S.680B8] Internal QPI Link Failure Detected.
Explanation: Internal QPI Link Failure Detected
Severity: Error
User response: Complete the following steps:
1. Check IBM support site for an applicable service bulletin or firmware update that applies to this error.
2. Inspect processor socket for foreign debris or damage. If debris is found remove debris.
3. If error recurs, or socket damage is found, replace the system board (Trained Service technician only) .
4. (Trained Service Technician Only) Replace the processor.
S.680B9 [S.680B9] External QPI Link Failure Detected.
Explanation: External QPI Link Failure Detected
Severity: Error
User response: Complete the following steps:
1. Check IBM support site for an applicable service bulletin or firmware update that applies to this error.
2. Inspect processor socket for foreign debris or damage. If debris is found remove debris.
3. If error recurs, or socket damage is found, replace the system board (Trained Service technician only) .
W.11004 [W.11004] A processor within the system has failed the BIST.
Explanation: Processor Self Test Failure Detected
Severity: Error
User response: Complete the following steps:
1. If the Processor or firmware was just updated, check IBM support site for an applicable service bulletin or
firmware update that applies to this Processor error.
2. (Trained service technician only) If there are multiple Processor’s, swap Processor’s to move affected Processor to
another Processor socket and retry. If problem follows the affected Processor, or this is a single Processor system,
replace the Processor. Inspect Processor socket on each Processor removal and replace system board first if
damaged or mis-aligned pins are found.
S.68005 W.11004
604
System x3650 M4 BD Type 5466: Installation and Service Guide

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System x3650 M4 BD Type 5466 and is the answer not in the manual?

IBM System x3650 M4 BD Type 5466 Specifications

General IconGeneral
Form Factor2U Rack
Operating System SupportMicrosoft Windows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server, VMware vSphere
MemoryUp to 768GB DDR3
StorageUp to 16x 2.5" hot-swap SAS/SATA HDDs/SSDs
Power Supply750W
Network InterfaceIntegrated quad-port Gigabit Ethernet
RAID SupportRAID 0, 1, 10
Remote ManagementIBM IMM2
ProcessorIntel Xeon E5-2600 v2 series

Related product manuals