S.51009 [S.51009] No system memory has been detected.
Explanation: No Memory Detected
Severity: Error
User response: Complete the following steps:
1. Make sure that one or more DIMMs are installed in the server.
2. If no memory fault is recorded in the logs and no DIMM connector error LEDs are lit, verify that all DIMM
connectors are enabled using the Setup utility or the Advanced Settings Utility (ASU).
3. Re-Install all DIMMs verifying the correct population sequence, according to the service information for this
product.
4. (Trained service technician only) Replace the processor.
5. (Trained service technician only) Replace the system board.
S.58008 [S.58008] A DIMM has failed the POST memory test.
Explanation: DIMM Failed Memory Test
Severity: Error
User response: Complete the following steps:
1. You must AC-cycle the system to re-enable affected DIMM connector or re-enable manually using F1 setup
2. If the node has been recently installed, serviced, moved, or upgraded, check to ensure that DIMMs are firmly
seated and that no foreign material can be seen in the DIMM connector. If either condition is observed, correct
and retry with the same DIMM. (Note: Event Log may contain a recent 00580A4 event denoting detected change
in DIMM population that could be related to this problem.)
3. If problem persists, replace the DIMM identified by LightPath and/or event log entry.
4. If problem re-occurs on the same DIMM connector, swap the other DIMMs on the same memory channel across
channels one at a time to a different memory channel or Processor. (check service information for this
product/Install guide for population requirements for sparing/paring modes). If problem follows a moved DIMM
to a different memory channel, replace that DIMM.
5. Check IBM support site for an applicable service bulletin or firmware update that applies to this memory error.
6. (Trained service technician only) If problem stays with the original DIMM connector, re-inspect DIMM connector
for foreign material and remove, if found. If connector is damaged, replace system board.
7. (Trained service technician only) Remove affected Processor and inspect Processor socket pins for damaged or
mis-aligned pins. If damage is found, or this is an upgrade Processor, replace system board. If there are multiple
Processor’s, swap Processor’s to move affected Procesor to another Processor socket and retry. If problem follows
the affected Processor (or there is only one Processor), replace the affected Processor.
8. (Trained Service technician only) Replace the system board.
S.51009 S.58008
Appendix B. UEFI/POST error codes 603

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System x3650 M4 BD Type 5466 and is the answer not in the manual?

IBM System x3650 M4 BD Type 5466 Specifications

General IconGeneral
Form Factor2U Rack
Operating System SupportMicrosoft Windows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server, VMware vSphere
MemoryUp to 768GB DDR3
StorageUp to 16x 2.5" hot-swap SAS/SATA HDDs/SSDs
Power Supply750W
Network InterfaceIntegrated quad-port Gigabit Ethernet
RAID SupportRAID 0, 1, 10
Remote ManagementIBM IMM2
ProcessorIntel Xeon E5-2600 v2 series

Related product manuals