CIM Information
The prefix of the message ID and the sequence number that is used by the
CIM message registry.
SNMP Trap ID
The SNMP trap ID that is found in the SNMP alert management
information base (MIB).
Automatically contact Service
If this field is set to Yes, and you have enabled Electronic Service Agent
(ESA), IBM Support will be notified automatically if the event is generated.
While you wait for IBM Support to call, you can perform the
recommended actions for the event.
User response
The actions that you should perform to solve the event.
Perform the steps listed in this section in the order shown until the
problem is solved. After you perform all of the actions that are described
in this field, if you cannot solve the problem, contact IBM Support.
Note: This list includes error codes and messages that might not apply to
this machine type and model.
Below is the list of IMM2 error messages and suggested actions to correct the
detected server problems. For more information about IMM2, see the Integrated
Management Module II User's Guide at http://www.ibm.com/support/entry/portal/
docdisplay?lndocid=MIGR-5089484..
IMM Events that automatically notify Support
You can configure the Integrated Management Module II (IMM2) to automatically
notify Support (also known as call home) if certain types of errors are encountered.
If you have configured this function, see the table for a list of events that
automatically notify Support.
Table 16. Events that automatically notify Support
Event ID Message String
Automatically
Notify
Support
40000086-00000000 Test Call Home Generated by user [arg1]. Yes
40000087-00000000 Manual Call Home by user [arg1]: [arg2]. Yes
80010202-0701ffff Numeric sensor
[NumericSensorElementName] going low
(lower critical) has asserted. (CMOS
Battery)
Yes
80010902-0701ffff Numeric sensor
[NumericSensorElementName] going high
(upper critical) has asserted. (SysBrd 12V)
Yes
806f0021-2201ffff Fault in slot
[PhysicalConnectorSystemElementName] on
system [ComputerSystemElementName].
(No Op ROM Space)
Yes
306 System x3650 M5 Type 5462: Installation and Service Guide

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System x3650 M5 and is the answer not in the manual?

IBM System x3650 M5 Specifications

General IconGeneral
Processor CoresUp to 22 cores per processor
Memory Slots24 DIMM slots
Form Factor2U rack server
ProcessorIntel Xeon E5-2600 v3/v4
MemoryUp to 1.5 TB (24x 64 GB LRDIMMs)
RAID SupportRAID 0, 1, 5, 6, 10, 50, 60
Network4x 1 GbE ports standard, optional 10 GbE
Power SupplyUp to 2x redundant hot-swap 550W, 750W, or 900W power supplies
Operating System SupportWindows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server, VMware
ManagementIntegrated Management Module (IMM) v2.1
StorageUp to 24 x 2.5" or 12 x 3.5" drives