EasyManuals Logo

IBM System x3650 M5 User Manual

IBM System x3650 M5
1010 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #91 background image
v For information about power-supply problems, see “Solving power problems”
on page 111, “Power problems” on page 100, and “Power-supply LEDs” on page
78.
v For intermittent problems, check the event log; see “Event logs” on page 81 and
Appendix C, “DSA diagnostic test results,” on page 837.
Performing the checkout procedure
Use this information to perform the checkout procedure.
About this task
To perform the checkout procedure, complete the following steps:
Procedure
1. Is the server part of a cluster?
v No: Go to step 2.
v Yes: Shut down all failing servers that are related to the cluster. Go to step 2.
2. Complete the following steps:
a. Check the power supply LEDs (see “Power-supply LEDs” on page 78).
b. Turn off the server and all external devices.
c. Check all internal and external devices for compatibility at
http://www.ibm.com/systems/info/x86servers/serverproven/compat/us/.
d. Check all cables and power cords.
e. Set all display controls to the middle positions.
f. Turn on all external devices.
g. Turn on the server. If the server does not start, see “Troubleshooting by
symptom” on page 88.
h. Check the system-error LED on the operator information panel. If it is lit,
check the LCD system information display panel (see “LCD system
information display panel” on page 22).
i. Check for the following results:
v Successful completion of POST (see “POST” on page 84 for more
information)
v Successful completion of startup, which is indicated by a readable display
of the operating-system desktop
3. Is there a readable image on the monitor screen?
v No: Find the failure symptom in “Troubleshooting by symptom” on page 88;
if necessary, see “Solving undetermined problems” on page 115.
v Yes: Run DSA (see “Running the DSA Preboot diagnostic programs” on page
86).
If DSA reports an error, follow the instructions in Appendix C, “DSA
diagnostic test results,” on page 837.
If DSA does not report an error but you still suspect a problem, see
“Solving undetermined problems” on page 115.
Chapter 3. Troubleshooting 75

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System x3650 M5 and is the answer not in the manual?

IBM System x3650 M5 Specifications

General IconGeneral
Processor CoresUp to 22 cores per processor
Memory Slots24 DIMM slots
Form Factor2U rack server
ProcessorIntel Xeon E5-2600 v3/v4
MemoryUp to 1.5 TB (24x 64 GB LRDIMMs)
RAID SupportRAID 0, 1, 5, 6, 10, 50, 60
Network4x 1 GbE ports standard, optional 10 GbE
Power SupplyUp to 2x redundant hot-swap 550W, 750W, or 900W power supplies
Operating System SupportWindows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server, VMware
ManagementIntegrated Management Module (IMM) v2.1
StorageUp to 24 x 2.5" or 12 x 3.5" drives

Related product manuals