Table 16. Events that automatically notify Support (continued)
Event ID Message String
Automatically
Notify
Support
806f010c-2015ffff Uncorrectable error detected for
[PhysicalMemoryElementName] on
Subsystem [MemoryElementName]. (DIMM
21)
Yes
806f010c-2016ffff Uncorrectable error detected for
[PhysicalMemoryElementName] on
Subsystem [MemoryElementName]. (DIMM
22)
Yes
806f010c-2017ffff Uncorrectable error detected for
[PhysicalMemoryElementName] on
Subsystem [MemoryElementName]. (DIMM
23)
Yes
806f010c-2018ffff Uncorrectable error detected for
[PhysicalMemoryElementName] on
Subsystem [MemoryElementName]. (DIMM
24)
Yes
806f010c-2581ffff Uncorrectable error detected for
[PhysicalMemoryElementName] on
Subsystem [MemoryElementName]. (All
DIMMS)
Yes
806f010d-0400ffff The Drive [StorageVolumeElementName]
has been disabled due to a detected fault.
(Drive 0)
Yes
806f010d-0401ffff The Drive [StorageVolumeElementName]
has been disabled due to a detected fault.
(Drive 1)
Yes
806f010d-0402ffff The Drive [StorageVolumeElementName]
has been disabled due to a detected fault.
(Drive 2)
Yes
806f010d-0403ffff The Drive [StorageVolumeElementName]
has been disabled due to a detected fault.
(Drive 3)
Yes
806f010d-0404ffff The Drive [StorageVolumeElementName]
has been disabled due to a detected fault.
(Drive 4)
Yes
806f010d-0405ffff The Drive [StorageVolumeElementName]
has been disabled due to a detected fault.
(Drive 5)
Yes
806f010d-0406ffff The Drive [StorageVolumeElementName]
has been disabled due to a detected fault.
(Drive 6)
Yes
806f010d-0407ffff The Drive [StorageVolumeElementName]
has been disabled due to a detected fault.
(Drive 7)
Yes
806f010d-0408ffff The Drive [StorageVolumeElementName]
has been disabled due to a detected fault.
(Drive 8)
Yes
Appendix A. Integrated management module II (IMM2) error messages 309

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System x3650 M5 and is the answer not in the manual?

IBM System x3650 M5 Specifications

General IconGeneral
Processor CoresUp to 22 cores per processor
Memory Slots24 DIMM slots
Form Factor2U rack server
ProcessorIntel Xeon E5-2600 v3/v4
MemoryUp to 1.5 TB (24x 64 GB LRDIMMs)
RAID SupportRAID 0, 1, 5, 6, 10, 50, 60
Network4x 1 GbE ports standard, optional 10 GbE
Power SupplyUp to 2x redundant hot-swap 550W, 750W, or 900W power supplies
Operating System SupportWindows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server, VMware
ManagementIntegrated Management Module (IMM) v2.1
StorageUp to 24 x 2.5" or 12 x 3.5" drives