8007030d-2582ffff Sensor [SensorElementName] has transitioned to non-recoverable from a less severe state.
(RAID Vol State)
Explanation: This message is for the use case when an implementation has detected a Sensor transitioned to
non-recoverable from less severe.
May also be shown as 8007030d2582ffff or 0x8007030d2582ffff
Severity: Error
Alert Category: Critical - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0524
SNMP Trap ID: 50
Automatically notify Support: No
User response:
1. Run the hard disk drive diagnostic test on drive n.
2. Reseat the following components: a. Hard disk drive (wait 1 minute or more before reinstalling the drive) b.
Cable from the system board to the backplane
3. Replace the following components one at a time, in the order shown, restarting the server each time: a. Hard
disk drive b. Cable from the system board to the backplane c. Hard disk drive backplane (n = hard disk drive
number)
80070608-0a01ffff Sensor [SensorElementName] has transitioned to non-recoverable.
Explanation: This message is for the use case when an implementation has detected a Sensor transitioned to
non-recoverable.
May also be shown as 800706080a01ffff or 0x800706080a01ffff
Severity: Error
Alert Category: Critical - Power
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0530
SNMP Trap ID: 4
Automatically notify Support: No
User response: If the specified sensor is PS n 12V OC Fault, complete the following steps until the problem is
solved:
1. Use the IBM Power Configurator utility to determine current system power consumption. For more information
and to download the utility, go to http://www-03.ibm.com/systems/bladecenter/resources/powerconfig.html.
2. Follow actions in "Power Problems and Solving Power Problems".
If the specified sensor is PS n 12V OV Fault, complete the following steps until the problem is solved:
1. Check power supply n LED.
2. Remove the failing power supply.
3. (Trained technician only) Replace the system board. (n = power supply number)
If the specified sensor is PS n 12V UV Fault, complete the following steps until the problem is solved:
1. Check power supply n LED.
2. Remove the failing power supply.
3. Follow actions in "Power Problems and Solving Power Problems".
4. (Trained technician only) Replace the system board. (n = power supply number)
If the specified sensor is PS n 12Vaux Fault, complete the following steps until the problem is solved:
8007030d-2582ffff • 80070608-0a01ffff
Appendix A. Integrated management module II (IMM2) error messages 409