806f020d-041dffff Failure Predicted on drive [StorageVolumeElementName] for array
[ComputerSystemElementName]. (Drive 29)
Explanation: This message is for the use case when an implementation has detected an Array Failure is Predicted.
May also be shown as 806f020d041dffff or 0x806f020d041dffff
Severity: Warning
Alert Category: System - Predicted Failure
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0168
SNMP Trap ID: 27
Automatically notify Support: Yes
User response:
1. Run the hard disk drive diagnostic test on drive n.
2. Reseat the following components: a. Hard disk drive b. Cable from the system board to the backplane.
3. Replace the following components one at a time, in the order shown, restarting the server each time: a. Hard
disk drive. b. Cable from the system board to the backplane. c. Hard disk drive backplane. (n = hard disk drive
number)
806f020d-041effff Failure Predicted on drive [StorageVolumeElementName] for array
[ComputerSystemElementName]. (Drive 30)
Explanation: This message is for the use case when an implementation has detected an Array Failure is Predicted.
May also be shown as 806f020d041effff or 0x806f020d041effff
Severity: Warning
Alert Category: System - Predicted Failure
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0168
SNMP Trap ID: 27
Automatically notify Support: Yes
User response:
1. Run the hard disk drive diagnostic test on drive n.
2. Reseat the following components: a. Hard disk drive b. Cable from the system board to the backplane.
3. Replace the following components one at a time, in the order shown, restarting the server each time: a. Hard
disk drive. b. Cable from the system board to the backplane. c. Hard disk drive backplane. (n = hard disk drive
number)
806f020d-041dffff • 806f020d-041effff
Appendix A. Integrated management module II (IMM2) error messages 493