Loading...
806f090c-200effff [PhysicalMemoryElementName] on Subsystem [MemoryElementName] Throttled. (DIMM 14)
Explanation: This message is for the use case when an implementation has detected Memory has been Throttled.
May also be shown as 806f090c200effff or 0x806f090c200effff
Severity: Warning
Alert Category: System - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0142
SNMP Trap ID: 22
Automatically notify Support: No
User response:
1. Reseat the DIMM, and then restart the server.
2. Replace DIMM n. (n = DIMM number)
806f090c-200fffff [PhysicalMemoryElementName] on Subsystem [MemoryElementName] Throttled. (DIMM 15)
Explanation: This message is for the use case when an implementation has detected Memory has been Throttled.
May also be shown as 806f090c200fffff or 0x806f090c200fffff
Severity: Warning
Alert Category: System - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0142
SNMP Trap ID: 22
Automatically notify Support: No
User response:
1. Reseat the DIMM, and then restart the server.
2. Replace DIMM n. (n = DIMM number)
806f090c-2010ffff [PhysicalMemoryElementName] on Subsystem [MemoryElementName] Throttled. (DIMM 16)
Explanation: This message is for the use case when an implementation has detected Memory has been Throttled.
May also be shown as 806f090c2010ffff or 0x806f090c2010ffff
Severity: Warning
Alert Category: System - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0142
SNMP Trap ID: 22
Automatically notify Support: No
User response:
1. Reseat the DIMM, and then restart the server.
2. Replace DIMM n. (n = DIMM number)
806f090c-200effff 806f090c-2010ffff