Table 7. Integrated management module error messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 4, “Parts listing, Type 7377 server,” on page 125 to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Message Severity Description Action
Memory DIMM disabled for
One of the DIMMs on
Memory Subsystem One of
the DIMMs.
Info DIMM disabled
1. Make sure the DIMM is installed
correctly (see “Installing a
memory module” on page 162
for memory population).
2. If the DIMM was disabled
because of a memory fault
(memory uncorrectable error or
memory logging limit reached),
follow the suggested actions for
that error event and restart the
server.
3. Check the IBM support website
for an applicable retain tip or
firmware update that applies to
this memory event. If no
memory fault is recorded in the
logs and no DIMM connector
error LED is lit, you can
re-enable the DIMM through the
Setup utility or the Advanced
Settings Utility (ASU).
Memory DIMM disabled for
DIMM n Status on Memory
Subsystem DIMM n Status.
(n = DIMM number)
Info DIMM disabled
1. Make sure the DIMM is installed
correctly (see “Installing a
memory module” on page 162).
2. If the DIMM was disabled
because of a memory fault
(memory uncorrectable error or
memory logging limit reached),
follow the suggested actions for
that error event and restart the
server.
3. Check the IBM support website
for an applicable retain tip or
firmware update that applies to
this memory event. If no
memory fault is recorded in the
logs and no DIMM connector
error LED is lit, you can
re-enable the DIMM through the
Setup utility or the Advanced
Settings Utility (ASU).
Numeric sensor Ambient
Temp going high (upper
critical) has asserted.
Error An upper critical sensor going high
has asserted.
Make sure that the fans are
operating, that there are no
obstructions to the airflow, that the
air baffle is in place and correctly
installed, and that the server cover
is installed and completely closed.
110 IBM System x3630 M3 Type 7377: Problem Determination and Service Guide

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM x3630 M3 7377 and is the answer not in the manual?

IBM x3630 M3 7377 Specifications

General IconGeneral
Product FamilySystem x
Machine Type7377
Max Processors2
ChipsetIntel 5520
Memory Slots12 DIMM slots
ProcessorIntel Xeon 5600 series
MemoryUp to 192 GB
RAID SupportRAID 0, 1, 10, 5, 50
Network Interface2 x Gigabit Ethernet
Power SupplyHot-swap, redundant
Operating System SupportMicrosoft Windows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server, VMware

Related product manuals