11-23
11. ABOUT THE DV GATEWAY FUNCTION
Troubleshooting
D Troubleshooting for the Access Point mode operation
PROBLEM POSSIBLE CAUSE SOLUTION REFERENCE
After your call, the repeater
replies “RX” or “RPT?” and
the Access Point call sign and
ID sufx “G.”
The Remote D-STAR transceiver’s
call sign has not been set to the
transceiver.
Set the Remote transceiver’s
call sign has not been set to the
transceiver.
The Remote
D-STAR
transceiver’s
instruction
manual
The Remote D-STAR transceiver’s
call sign has not been registered at
a gateway server.
Register The Remote D-STAR
transceiver’s call sign at a gateway
server.
The Terminal/AP call sign that is set
in the transceiver, RS-MS3A, or RS-
MS3W has not been registered to
the RS-RP3C as the access point.
When using the Internal Gateway
function, register the Terminal/AP
call sign that is set in the transceiver
to the RS-RP3C as the access point.
p. 11-8
When using the External Gateway
function, register the Terminal/AP
call sign that is set in the RS-MS3A
or RS-MS3W to the RS-RP3C as
the access point.
RS-MS3W,
RS-MS3A’s
instruction
manual
Destination station’s call sign (UR)
has not been registered to the
gateway server, or the registered
contents do not match your
transceiver’s setting.
Check the destination station’s
register information.
A wrong destination repeater’s call
sign is set to “TO.”
Set the correct destination
repeater’s call sign to “TO.”
p. 11-15
The settings are wrong. When using the Internal Gateway
function, correctly set the
transceiver’s Internal Gateway
settings.
p. 11-8
When using the External Gateway
function correctly set the RS-MS3W
or the RS-MS3A.
RS-MS3W,
RS-MS3A’s
instruction
manual
Destination station that uses the
Terminal mode or Access Point
mode does not transmit periodically.
Destination station makes a call.
After your call, the repeater
replies ’RPT?’ and the access
repeater’s call sign.
The repeater cannot connect to the
destination repeater.
The repeater is busy.
Wait for a while, and try again.
“L” appears on the LCD. While receiving through the Internet,
some packets may be lost due to
network error (poor data throughput
performance).
Wait for a while, and try again.
L When the transceiver receives
corrupted data, and misidenties
it is as Packet Loss, “L” is
displayed.
“DV” and “FM” icons
alternately blink.
While in the DV mode, an FM signal
is received.
Use a different operating frequency
until there are no FM signals on the
original frequency.
You can transmit, but cannot
receive from the destination
repeater.
A Global IP address is not used. Check the Internet connection and
use a Global IP address.
pp. 11-4 ~ 11-7
The router or mobile router’s port is
not correctly forwarded.
Forward the router or mobile
router’s correct port.
pp. 11-4, 11-7
The rewall is blocking the
necessary port.
Check your rewall settings. p. 11-10