20
printer and check TPH
status.
Heater Not Found x x x x Retransfer
head connect
check
Retransfer head is not
installed, or cable is not
connected, or abnormal
temperature. Power off
and check Retransfer
head status and
temperature.
Check Heater
BHeater Not
Found
x x x x Bend
Retransfer
head connect
check
Bend retransfer head is
not installed, or cable is
not connected, or
abnormal temperature.
Power off and check
bend retransfer head
status and temperature.
Check BHeater
Heater Broken! x x x x Retransfer
head broken
or damaged
Retransfer head is broken
or damaged. Power off
and check retransfer head
status and temperature.
Check Heater
BHeater Broken! x x x x Bend
Retransfer
head broken
or damaged
Bend retransfer head is
broken or damaged.
Power off and check
bend retransfer head
status and temperature.
Check BHeater
Heater Error! x x x x Retransfer
head
Safety Error
Retransfer head has
safety error. Power off
and check retransfer head
status and temperature.
.
Check Heater
BHeater Error! x x x x Bend
Retransfer
head
Safety Error
Bend retransfer head has
safety error. Power off
and check bend
retransfer head status
and temperature.
Check BHeater
TPH Warming UP X x x x Standby for
TPH temp
rising.
SMART’s temperature
drops below 1’C.
The normal temperature
is 15C~35C.
Temperature xxx
Spool Error Delete
spool and
cancel
x x System
reset
Spool error
Error occurs while receive
spool print data. KEY0 is
delete and cancel, KEY3 is
System Reset
<Cancel Reset>
xxxxxxxxxxxxxxx+ Retry x x Cancel and
Initialization
Error occurs
while printing
Error occurs while
printing. KEY0 is retry,
KEY3 is cancel printing
(Refer to Printer LCD
Error Table)
‘+’ is displayed at the end
of first line if there are
more than two errors
<Retry Cancel>

Table of Contents