Loading...
47
2
INSTALLATION PROCEDURE
302.061
ERROR CAUSE SOLUTION
The feed motor has stopped and is
not restarting.
There is a problem with the drive of
the motor.
Check the drive: The green LED of
the control panel must be lighted.
The motor is shorted Check the shorted motor.
The temperature of the drive heat
sink has reached the maximum per-
missible value
Let the drive cool and wait about 15
minutes before powering on again.
Check if the problem occurs again.
ERROR CAUSE SOLUTION
During the facing stroke, the bar has
met an obstacle before reaching the
section defined by
parameter 11
.
There is an obstacle in the spindle
Check that there are no impedi-
ments, or diameter differences such
as to prevent the movement of the
bar .
Check the number of revolutions of
the spindle.
Encoder fault.
Check that the encoder is driven
correctly in the rotation.
Check on the display the position of
the bar pusher carriage, and verify
that the position change indicated
corresponds to the actual movement.
Card fault.
Contact IEMCA technical assi-
stance.
26
Error:protected moto
rdrive
27
impu l s e s
Error: s tat ionary pos
ition before
C
parameter
11
IDM - 61.021 Ec.0
facing flag

Table of Contents