INSTALLATION PROCEDURE
302.061
ERROR CAUSE SOLUTION
The bar feeder has stopped due to
a fault.
Examples: Wrong bar-pusher move-
ment, bar not loaded in collet, bar
remnant missing, bar missing, etc..
Correct fault and reset with STOP
push-button.
ERROR CAUSE SOLUTION
The bar feeder is not locked but is
running.
The axial displacement device is not
locked.
Lock the axial displacement device.
The sensor is not providing the OK
signal.
Check that the sensor issues the
signal when the axial displacement
device is locked.
Check the correct operation of the
sensor.
ERROR CAUSE CURE
After the key has been
pressed on the bar feeder keybo-
ard, this message appears.
The “MANUAL” mode was actuated
from the remote control panel on the
lathe.
Move the selector switch of the
remote control panel to the “AUTO-
MATIC” position.
28
Re s e t wi t h STOP! ! !
29
Er ror : ax i a l d i sp l ac e
me n t n o t l o c k e d
30
(Error: . . . )
31
Er ror :Manua l f rom co
ntrol panel