52
2
INSTALLATION PROCEDURE
302.061
ERROR CAUSE SOLUTION
Signals that the charge of the PLC
batter is low.
Battery charge low.
Replace the battery within one day
(See Chapter 9 of the Use and
Maintenance Manual).
ERROR SOLUTION
It indicates that the bar guide is not in the correct
position.
Using the keyboard controls, regain the correct position by
lowering the bar pusher.
ERROR SOLUTION
It indicates that the bar pusher is not in the correct
position. Using the keyboard controls, regain the correct position.
ERROR CAUSE SOLUTION
The bar pusher did not move from
the "UPWARD" to the
"DOWNWARD" position.
The movement is hindered by an
obstacle. Remove the obstacle.
The
S2
microswitch (the bar pusher
downwards device) is out of position
or damaged.
Check the microswitch position or
replace the microswitch.
45
PLC battery exhauste
d
46
Ba r f e ede r l i f t ed
47
Bar drop cont ro l on
48
Ba r pu s he r upward