Programming manual
Programming terminals 49
Tamper sensor sensitivity.
Varies from 1 (least sensitive) to 10 (most sensitive).
The default setting is 3.
Dual technology detector
Curtain detector
Outdoor terminal
Tamper sensitivity
Shock Sensit.
Anti-mask detector sensitivity
Varies from 1 (least sensitive) to 10 (most sensitive).
The default setting is 3.
Dual technology detector
Curtain detector
Anti-mask sensitivity
Shock Sensit.
Selection of the magnetic reed contact:
• Magnet - long side, for detection using the long
side of the magnetic contact.
• Magnet - short side, for detection using the short
side of the magnetic contact.
• Both magnets - for detection using both sides of
the magnetic contact.
Magnetic contact Reed relay type
MagnetLongSide
MagnetShortSide
BothMagnets
Shock detector sensitivity
Varies from 1 (least sensitive) to 10 (most sensitive).
The default setting is 1.
MC200 magnetic contact Shock sensor
Shock sensitiv.
Maximum angle within which the movement is not
signalled, from 1 (minimum tilt) to 10 (about 90 °
from the resting position); 1 is the default preset
value.
MC200 magnetic contact Tilt
Tilt
If the device is programmed to detect shock waves
(bangs or vibration), this parameter refers to the
time within which they must be detected.
If the device is configured to detect tilting, this
parameter refers to the time with which the angle
variation will be signalled.
from 1 to 125 (100msec or sec)
MC200 magnetic contact Shock/Tilt time
Tilt duration
Checkbox to disable the corresponding detector
Passive infrared detector
Outdoor terminal
Dual technology detector
Curtain detector
MC200 magnetic contact
Disabled
Not available
Table 6-10: Wireless detector sensitivity
Table 6-11: Real-time for wireless zones
Parameter Software section
Real-time
Clicking on the Real-time button displays the current values of the following features
of the wireless device:
Wireless
expansion,
Selected terminal
Reading level
The value read by each detector of the device is displayed on a
bar which indicates the alarm threshold by means of a colour
change from green to red.
Battery charge level
Percentage of the device battery charge.
Signal reception
This is a series of notches that represent the signal reception
strength on the device as received by the Air2-BS200
transceiver.
RF analysis
This button opens a window which allows you to monitor the
signal variations transmitted by the device and any detected
background noise.