Chapter A — Error Handling
162 ESim for the PC4 and PF8 Printers Programmer’s Reference Manual
This table lists the error responses and codes reported when
Command US is off.
Error Responses and Codes Reported When Command US Is Off
Error
Code
Error
Type
Description LED Serial
Response to
Command ^ee
No error GRN -
01 A Syntax error GRN - 01<CRLF>
02 B Object exceeds image buffer
border
ORA [XOFF] 02<CRLF>
03 A Data length error GRN 03<CRLF>
04 A Insufficient memory to store
data
GRN - 04<CRLF>
05 A Memory configuration error GRN - 05<CRLF>
07 C Out of media, marked with
Pnnn = Number of remaining
labels.
RED [XOFF] 07<CRLF>
08 A Form or image name duplicate. GRN - 08<CRLF>
09 A Form or image not found GRN - 09<CRLF>
11 D Printhead up (cover open) RED [XOFF] 11<CRLF>
13 E LTS detection waiting, peel
pause.
- - 13<CRLF>
16 A No form was retrieved before
“?<CRLF>” was entered.
GRN - 16<CRLF>
17 C Out of ribbon, marked with
Rnnn = Number of remaining
labels.
RED [XOFF] 17<CRLF>
50 A Does not fit in area specified. GRN - 50<CRLF>
51 A Data length too long GRN - 51<CRLF>
61 D High motor temperature BLNK
RED
[XOFF] 61<CRLF>
62 D High printhead temperature BLNK
RED
[XOFF] 62<CRLF>
71 F Wait after default setup. GRN [XOFF] 71<CRLF>
72 F Flashing not completed RED [XOFF] 72<CRLF>
73 F Download error RED [XOFF] 73<CRLF>