Chapter 3 — Designing Bar Code Labels
ESim for the PC4 and PF8 Printers Programmer’s Reference Manual 27
It is not necessary to reset the counter start value. The counter keeps
track of the last number issued as long as the power remains switched
on and the counter is updated according to instructions in the form.
Once a form has been retrieved, you can use it over and over again
until you retrieve another form. All variable input data and counter
values are stored in the volatile memory, which means it is lost when
the printer loses power. If prompts are enabled, existing data and
counter values are displayed on the screen after the related prompt.
Any input data can be overwritten at will.
Command Explanation
CR/LF to start command structure
FR“TEST”
Retrieve form
?
Call for variables
EASYCODER
Substitute variable V00
501SA
Substitute variable V01
Dan
Substitute variable V02
CR/LF to use existing counter value
P1,2
Print 2 copies of a single label
Command Explanation
?
Call for variables in the same form
CR/LF to use existing data in V00
CR/LF to use existing data in V01
Sam
Substitute data in variable V02
200000
Substitute counter start value
P1,1
Print 1 copy of 1 label