Chapter 4 — ESim Commands
52 ESim for the PC4 and PF8 Printers Programmer’s Reference Manual
Remarks: If parameter www (maximum print width) gives less space than
required by the sum of parameters x- (module witch) and l-
(maximum column count), error condition 50 occurs.
Also, if parameter hhh (maximum print height) gives less space than
required by the sum of parameters y- (set bar height) and r-
(maximum row count), error condition 50 occurs.
Example:
N
b40,40,P,400,300,p40,340,20,f1,x3,y10,r60,l5,“AB
CDEFGHIJK1234567890abcdefghijk”
P1
d- Print code words:
0 = Values of code words not printed (default).
1 = Values of code words printed.
x- Module width. Legal values are 2-9.
y- Set bar height. Legal values are 4-99 dots high.
r- Maximum row count, refer to PDF417
specifications.
l- Maximum column count, refer to PD417
specifications.
t- Truncated flag:
0 = Not truncated.
1 = Truncated.
o- Rotation:
0 = 0° rotation clockwise.
1 = 90° rotation clockwise.
2 = 180° rotation clockwise.
3 = 270° rotation clockwise.
“DATA” Represents a fixed data field.
b - PDF417 Command Parameter Descriptions (continued)
Parameter Description