Chapter 4 — ESim Commands
60 ESim for the PC4 and PF8 Printers Programmer’s Reference Manual
The table below illustrates how leading space characters (“ ”) in DATA
are influenced by next character at wrap around. If next position is a
digit with wrap around (9
0), space is incremented to digit 1. If next
position is a letter with wrap around (Z
A), space is incremented to
letter A.
Example:
FK“TEST5”
FS“TEST5”
C0,5,L,+1,“Start value CNT 0”
C1,5,R,+1,N,“Start value N-CNT 1”
C2,5,C,+1,A,“Start value A-CNT 2”
C3,5,N,+1,B,“Start value B-CNT 3”
A50,050,0,3,1,1,N,“Cnt Default, left
justified :“C0”:”
A50,100,0,3,1,1,N,"Cnt Numerical, right
justified :“C1”:”
A50,150,0,3,1,1,N,“Cnt Alpha, center
justified :“C2”:”
C- Counter Command Parameters
P
5
Counter Command
Start
Data
Data after p4
=+1
Data after p4
=+2
N C0,3,C,+1,N,“Numeric
al”
“99”
“999”
g
g
“100”
“000”
g
g
“101”
“001”
A C0,3,C,+1,A,“Alpha”
(if no P5 parameter is
included, method A is
selected by default).
“ A9”
“ Z9”
“0Z9”
“ ZZ”
“ZZ9”
g
g
g
g
g
“ B0”
AA0”
“1A0”
AAA”
AA0”
g
g
g
g
g
“ B1”
AA1”
“1A1”
AAB”
AA1”
B C0,3,C,+1,B,“Alpha-
num”
“ 99”
“ A9”
“ 9Z”
“ ZZ”
“ZZZ”
g
g
g
g
g
“ 9A
“ AA”
“ A0”
“100”
“000”
g
g
g
g
g
“ 9B”
“ AB”
“ A1”
“101”
“001”

Table of Contents