SERVICE MANUAL
Invacare
®
- Bora/Spectra XTR
28
Component Check Remedy Notes
Drive units,
coupling
mechanism
• Check functions in
drive and push
modes
• Check coupling
mechanism
• Replace motor if
necessary.
• Tighten
screws/nuts,
adjust or replace if
necessary
Legrests
• Check welded
seams, interlocking,
screws, footplates
• Tighten, replace if
necessary
Power legrests
(if fitted)
• Check cable
• Check contacts
• check functions
• Replace cable if
necessary
Lighting (if
fitted)
• Check cable
• Check function
• Replace lamp or
cable if necessary
Batteries
• Check batteries for
damage
• Replace batteries
if necessary
See chapter 7.7.
• Check battery
voltage
• Charge batteries
See operating
manual
• Check contacts and
terminals
• Clean contacts
and terminals
Please refer to the
safety information
in Chapter 7.7 for
handling batteries
Battery case
• Check locking
system, it must
engage completely.
• Replace if
necessary
Remote /
electronics
module
• Remote, status
display blinking
• Evaluate
error/blink code
• Fixings • Tighten fixings,
replace if
necessary
• Cables and
connecting plugs
• Tighten cables
and connecting
plugs, replace if
necessary
• Drive lever function • Replace drive
lever if necessary
• Replace remote if
necessary
• Power supply • Tighten cables
and connecting
plugs, replace if
necessary
Drive program
• Check drive
electronics program
version
• Update software if
newer version
available.
See chapter 7.6.

Table of Contents