SERVICE MANUAL
Invacare
®
- Bora/Spectra XTR
28
Component Check Remedy Notes
Drive units,
coupling
mechanism
Check functions in
drive and push
modes
Check coupling
mechanism
Replace motor if
necessary.
Tighten
screws/nuts,
adjust or replace if
necessary
Legrests
Check welded
seams, interlocking,
screws, footplates
Tighten, replace if
necessary
Power legrests
(if fitted)
Check cable
Check contacts
check functions
Replace cable if
necessary
Lighting (if
fitted)
Check cable
Check function
Replace lamp or
cable if necessary
Batteries
Check batteries for
damage
Replace batteries
if necessary
See chapter 7.7.
Check battery
voltage
Charge batteries
See operating
manual
Check contacts and
terminals
Clean contacts
and terminals
Please refer to the
safety information
in Chapter 7.7 for
handling batteries
Battery case
Check locking
system, it must
engage completely.
Replace if
necessary
Remote /
electronics
module
Remote, status
display blinking
Evaluate
error/blink code
Fixings Tighten fixings,
replace if
necessary
Cables and
connecting plugs
Tighten cables
and connecting
plugs, replace if
necessary
Drive lever function Replace drive
lever if necessary
Replace remote if
necessary
Power supply Tighten cables
and connecting
plugs, replace if
necessary
Drive program
Check drive
electronics program
version
Update software if
newer version
available.
See chapter 7.6.