SERVICE MANUAL
Invacare
®
- Bora/Spectra XTR
30
Problem Other
Symptoms
Possible
Cause
Solution Documentation
Replace carbon
brushes
See chapter 7.2.4.
Batteries
not being
charged
None Batteries
defective
Replace batteries See chapter 7.7.
LEDs blinking
on charging unit
Charging unit
defective
Replace charging
unit
See charging unit
operating manual
Mobility
device
runs too
slowly
None Remote
defective
Replace remote See chapter 7.10.
Batteries
defective
Replace batteries See chapter 7.7.
Electrical
adjustment
motor
does not
react
Remote shows
a blinking "E",
status diode on
lighting/actuator
module does
not go out even
if remote is
switched off or
disconnected.
Lighting /
actuator
module
defective
Replace lighting /
actuator module
See chapter 7.2.9.
None Cable
disconnected
or damaged
Safeguard cable
connection,
replace cable if
necessary
See chapter 7.9.
Electrical
adjusting
motor
defective
Check adjusting
motor
See chapter 7.17.
Remote
defective
Replace remote See chapter 7.10.

Table of Contents

Related product manuals