24
PROBLEM
OTHER
SYMPTOMS
POSSIBLE
CAUSE
SOLUTION
Documentation
Replace
transmission if
sealing ring
defective.
See chapter 8.17.1.
Transmission
losing oil
None Sealing ring on
drive shaft
defective
Check carbon
brushes for oil
wetting, replace
motor if brushes
wet
See chapters 8.17.1 and
8.17.2
Irregular
running
None Drive shaft
movable or bent
Check drive shaft,
replace
transmission if
defective.
See chapter 8.17.1.
Parts lost
None Parts lost
Reattach parts
once found.
Fuse burnt out,
cable defective
Check cabling and
replace fuse
See chapters 8.3.5 and
8.3.4
None
Batteries
defective
Replace batteries
See chapter 8.3.2.
Batteries not
being charged
LEDs blinking
on charging
unit
Charging unit
defective
Replace charging
unit
See charging unit
operating manual
Short
charging
period
None One of the
batteries could
be defective
Replace batteries
See chapter 8.3.2.
Remote
defective
Replace remote
See chapter 8.4.1.
Mobility aid
runs too
slowly
None
Batteries
defective
Replace batteries
See chapter 8.3.2.