Goodrive200 inverters Function codes
132
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
P24.07
Awake
frequency
0.00~P0.03(the Max. frequency)
20.00
Hz
P24.08
Setting
value of
hibernation
awake
0.00~100.0% 10.0%
P24.09
Mini
hibernation
time
0.0~3600.0s 5.0s
P24.10
Valid
auxiliary
motor
P24.10~P24.12 can make three motors to form a
simple system of water supply.
P24.10 is used to select the valid auxiliary motor.
0: No auxiliary motor
1: Auxiliary motor 1 valid
2: Auxiliary motor 2 valid
3: Auxiliary motor 1 and 2 valid
Setting range of P24.10: 0.0~3600.0s
Setting range of P24.11: 0.0~3600.0s
0
P24.11
Start/stop
delay time
of a
uxiliary
motor 1
5.0s
P24.12
Start/stop
delay time
of a
uxiliary
motor 2
5.0s
P24.13
R
eserved
0~1
0
P24.14
Reserved
0~1
0
P24.15
Reserved
0~1
0