Goodrive200 inverters Basic operation instruction
144
When the user selects the user-defined V/F curve function in Goodrive200 series inverters, they
can set the reference channel of voltage and frequency and the corresponding ACC/DEC time, or
the two can combination to form a real-time curve.
Note: the application of V/F curve separation can be used in many cases with various kinds of
power supply of the inverter. But the users should set and adjust the parameters with caution.
Incorrect parameters may cause damage to the inverter.
Function
code
Name
Detailed instruction of parameters Default
value
P00.00 Speed control mode
1: SVC
2: SVPWM control (applying to AM)
2
P00.03 Max. output frequency
P00.04~400.00Hz 50.00Hz
P00.04
Upper limit of the running
frequency
P00.05~P00.03 50.00Hz
P00.05
Lower limit of the running
frequency
0.00Hz~P00.04 0.00Hz
P00.11 ACC time 1 0.0~3600.0s Depend